KINBOOST

KB Series 100-200 kW Generator Sets

Diesel and gas sets from 100-200 kW with 57 engine configurations across 7 brands: open, silent, mobile and containerised builds, 50/60 Hz.

100-200 kW generator sets
Power band100-200 kWEngine options57BrandsVolvo Penta, Yuchai, KINBOOST, Perkins, Shangchai, Cummins, WeichaiFrequency50 / 60 HzCustomization
Open (weatherproof)SilentMobile / TrailerContainerizedATSAlternatorColor optionsOEM / ODM
Applications
Prime powerStandby backupRental fleetsIndustrial plantsConstructionMining
See how these sites are powered →
Request a quote for this modelFull datasheet, load-bank test report and O&M manual ship with the unit. See the document pack

What's included

  • Engine, alternator and controller coupled and tested as one set
  • Base frame with anti-vibration mounts; day tank or external tank per build
  • Silent canopy / trailer / container per selected build type
  • Battery set, exhaust silencer and flexible bellows
  • Factory load-bank test report (0 / 50 / 75 / 100% load)
  • Packing for sea freight; destination certificates per market
Open Type generator set built in this power band
Open Type
Silent Type generator set built in this power band
Silent Type
Mobile / Trailer Type generator set built in this power band
Mobile / Trailer Type
Containerized Type generator set built in this power band
Containerized Type

Engine variants & specifications

Indicative data based on engine OEM matching sheets. Fuel consumption calculated at 75% of prime rating.

ModelPrime powerEngine brandEngine modelCylindersDisplacementLube oilFuel @75%DimensionsWeight
KB-105GF105 kWVolvo PentaTAD750GE64.76 L20 L19.4 L/h2300*800*13771400 kg
KB-110GF110 kWPerkins1106A-70TG167 L16.6 L10387.6 L/h2410*930*16501500 kg
KB-110GF110 kWShangchai4HTAA4.3-G3664.3 L13 L19 L/h2500*760*16001250 kg
KB-110GF110 kWYuchaiYC4A190-D3044.8 L22 L13056.7 L/h2200*700*14501690 kg
KB-120GF120 kWCummins6BTAA5.9-G1265.88 L16 L22.4 L/h2500*910*13501450 kg
KB-120GF120 kWCumminsQSB6.7-G366.7 L24 L21 L/h2550*1120*15301450 kg
KB-120GF120 kWPerkins1106A-70TAG267.01 L16.6 L11331.9 L/h2410*930*16501600 kg
KB-120GF120 kWShangchai6HTAA6.5-G3264.3 L13 L20.7 L/h2300*830*13001700 kg
KB-120GF120 kWShangchaiSC7H205D266.5 L20 L22.1 L/h2650*760*16001450 kg
KB-120GF120 kWVolvo PentaTAD731GE67.15 L29 L22.6 L/h2500*850*14501400 kg
KB-120GF120 kWVolvo PentaTAD751GE67.15 L20 L22.6 L/h2500*1000*16001600 kg
KB-120GF120 kWWeichaiWP6D152E20066.75 L18 L22.6 L/h2500*930*15401200 kg
KB-120GF120 kWYuchaiYC6B205L-D2067.2 L17 L11654.9 L/h2500*980*13501668 kg
KB-120GF120 kWYuchaiYCD6Q23H8-21067.4 L22 L11654.9 L/h2650*760*16001450 kg
KB-100GF121 kWKINBOOSTR6105AZLD6––11425.8 L/h234*73*1201000 kg
KB-120GF132 kWKINBOOSTR6105IZLD6––12465.1 L/h234*73*1201050 kg
KB-135GF135 kWShangchai6HTAA6.5-G3566.5 L20 L23.3 L/h2400*970*15002100 kg
KB-144GF144 kWCumminsQSB6.7-G466.7 L24 L25.2 L/h2560*1240*15502169 kg
KB-145GF145 kWCummins6CTA8.3-G268.3 L24 L26.7 L/h2400*930*13501800 kg
KB-150GF150 kWShangchai6HTAA6.5-G3364.3 L20 L25.9 L/h2500*970*15002300 kg
KB-150GF150 kWShangchaiSC7H250D266.5 L20 L27.6 L/h2500*1000*15001330 kg
KB-150GF150 kWVolvo PentaTAD732GE67.15 L29 L29 L/h2500*1000*16001700 kg
KB-150GF150 kWVolvo PentaTAD752GE67.15 L29 L29 L/h2500*1000*16001550 kg
KB-150GF150 kWWeichaiWP7D185E31067.47 L20 L26.3 L/h2400*970*15002100 kg
KB-150GF150 kWYuchaiYC6A245-D3067.25 L22 L14568.7 L/h2560*980*16001700 kg
KB-150GF150 kWYuchaiYC6A245L-D2167.2 L22 L14568.7 L/h2600*980*13502041 kg
KB-150GF151 kWKINBOOSTR6105IZLD大泵6––14259.3 L/h234*73*1201100 kg
KB-150GF155 kWKINBOOSTR6110ZLD6––15333.2 L/h234*75*1301120 kg
KB-160GF160 kWCummins6CTAA8.3-G268.3 L24 L29.5 L/h2550*1000*14502196 kg
KB-160GF160 kWCumminsQSL8.9-G268.9 L28 L28 L/h2700*1100*15001800 kg
KB-160GF160 kWPerkins1106A-70TAG367.01 L16.6 L15109.2 L/h2550*930*16701800 kg
KB-160GF160 kWShangchai6DTAA8.9-G3168.8 L20 L27.6 L/h2500*980*15001520 kg
KB-160GF160 kWShangchaiSC8D280D268.8 L20 L29.5 L/h2450*980*15001520 kg
KB-160GF160 kWVolvo PentaTAD733GE612.1 L29 L30.2 L/h2600*1100*15301950 kg
KB-160GF160 kWVolvo PentaTAD753GE67.15 L29 L30.2 L/h2350*900*16502000 kg
KB-160GF160 kWWeichaiWP10D200E20069.7 L18 L30.2 L/h2850*1160*18001882 kg
KB-160GF160 kWYuchaiYCD6Q33H6-26067.4 L22 L15540.4 L/h2500*970*15002300 kg
KB-176GF176 kWPerkins1106A-70TAG467.01 L16.6 L16620.1 L/h2550*930*16701900 kg
KB-180GF180 kWCummins6CTAA8.3-G968.3 L24 L33.1 L/h2600*950*15002500 kg
KB-180GF180 kWCumminsQSL8.9-G368.9 L28 L31.5 L/h2600*1000*15002300 kg
KB-180GF180 kWShangchai6DTAA8.9-G3268.8 L20 L31 L/h2700*1040*15001750 kg
KB-180GF180 kWShangchaiSC9D310D268.8 L20 L33.1 L/h2520*980*15001540 kg
KB-180GF180 kWWeichaiWP7D240E31067.47 L20 L31.5 L/h2500*100*15001800 kg
KB-200GF200 kWCummins6YGAA8.9-G268.9 L28 L36.8 L/h2700*1000*15502268 kg
KB-200GF200 kWCummins6YGAA8.9-G369.9 L28 L36.8 L/h2600*1100*17001800 kg
KB-200GF200 kWCumminsNT855-GA614 L37 L36.1 L/h3000*1100*17502900 kg
KB-200GF200 kWCumminsQSL8.9-G468.9 L28 L35 L/h2800*1100*15502268 kg
KB-200GF200 kWCumminsQSNT-G6614 L37 L36.1 L/h3000*1050*17502900 kg
KB-200GF200 kWPerkins1506C-E88TAG268.7 L26.4 L20146.5 L/h2580*930*16702000 kg
KB-200GF200 kWShangchai6DTAA8.9-G3368.8 L27 L34.5 L/h2700*1040*15001750 kg
KB-200GF200 kWShangchaiSC9D340D268.8 L33 L36.8 L/h2700*980*15001750 kg
KB-200GF200 kWVolvo PentaTAD734GE612.1 L29 L37.7 L/h2550*1050*16002000 kg
KB-200GF200 kWVolvo PentaTAD754GE67.15 L29 L37.7 L/h2400*900*16502250 kg
KB-200GF200 kWWeichaiWP10D264E20069.7 L22 L37.7 L/h2800*1160*18002072 kg
KB-200GF200 kWWeichaiWP7D264E31067.47 L20 L35 L/h3100*1050*16502750 kg
KB-200GF200 kWYuchaiYC6MK350-D30610.34 L30 L22121.9 L/h2800*1100*17002570 kg
KB-200GF200 kWYuchaiYC6MK350L-D20610.3 L28 L22121.9 L/h3000*1100*15002808 kg

Features

OEM engine matching

Nine engine series matched to the same alternator and controller platform, so a brand swap never changes the rest of the set.

100% load-bank tested

Every set runs 0 / 50 / 75 / 100% before dispatch. Report and video ship with the machine.

Built for the grid you have

50 Hz and 60 Hz windings, any standard voltage, DER1/DER2 or DSE controllers to match your site.

Destination-ready

SONCAP, SASO, GOST/EAC and COC/PVoC documentation prepared before the container is sealed.

What your site takes away from the nameplate.

Hot, thin air carries less oxygen, so a set makes less power than the catalogue figure. This table is a planning guide for sizing, not a substitute for the derate curve in the formal datasheet.

Sea level to 500 m1.00
1,000 m0.965
1,500 m0.948
2,000 m0.93
3,000 m0.895

Worked example

  • A set rated 500 kW prime at reference conditions.
  • Site at 1,500 m altitude and 45 °C ambient.
  • Altitude factor 0.948, ambient factor 0.99.
  • Usable output is about 500 x 0.948 x 0.99, or 469 kW.

469 kW usable, against a 500 kW nameplate.

Full derating tables and site sizing

Prime, standby or continuous. The label changes the price.

The same machine carries three different numbers depending on which rating you buy. Sizing to the wrong one is the most expensive mistake in a generator project, so here is the definition we quote against.

ESPStandby power

Rated output available for the duration of a mains outage, with a limited annual running hour allowance. No overload capability. The cheapest rating, and the right one for backup only.

PRPPrime power

Rated output available continuously under varying load, with a 10% overload permitted for one hour in twelve. This is the rating most industrial and mining sites should buy.

COPContinuous power

Rated output available for unlimited hours at a constant load. No overload capability. Required where the set is the only source of power rather than a backup.

ISO 8528-1 defines the three ratings above. Reference conditions are 25 °C ambient, 100 m altitude and 30% relative humidity. Every value we publish is stated at those conditions unless the row says otherwise.

What arrives in the container besides the set.

Every unit ships with the documents below, prepared against its own serial number, plus whichever destination certificate your market requires.

Export-crated generator sets prepared for dispatch at the KINBOOST plant
  1. 01Commercial invoice and packing list
  2. 02Bill of lading or airway bill
  3. 03Certificate of origin (Form E / FTA as applicable)
  4. 04Signed load-bank test report with unit serial number
  5. 05Operation and maintenance manual
  6. 06Electrical schematic and control wiring diagram
  7. 07Spare parts list keyed to the unit serial number
  8. 08Warranty certificate

Request a quote for this model

Send the specification to our engineers and get a landed-price quotation within 48 hours.