Eight kinds of site. One range of machines.

Each of these punishes a generator set in a different way. Tell us which one is yours and we will specify for it, including altitude derating and cooling margin.

Mining & Quarry

Mining & Quarry

Dust, altitude and 24/7 duty. Filters clog, radiators foul and the set runs at higher altitude than the nameplate assumes.

What we change in the specification

  • Heavy-duty two-stage air filtration with a pre-cleaner
  • Oversized radiator and tropical-grade coolant for ambient above 40 C
  • Altitude-derated specification, confirmed before the contract
  • Bunded fuel tank sized for the longest refuelling interval on site
  • Containerised build with service access on both sides

Typical bands: 350 kW to 2000+ kW, containerised and paralleled

Every site punishes a set differently.

Altitude derating, dust, transfer time, low seasonal load or a fleet that moves every few weeks. Pick the closest match and we will specify against it rather than against a catalogue average.

Data Centres generator set application

Data Centres

A data hall measures a generator in seconds of transfer time and milliseconds of voltage sag, not in kVA.

  • N+1 or 2N configuration designed with your electrical consultant
  • Transfer under ten seconds, with the switchgear sequence witnessed at test
  • Low-vibration skids and acoustic treatment for occupied buildings

500 kW to 2000+ kW, paralleled and containerised

Healthcare generator set application

Healthcare

A hospital load is unforgiving: lifts, theatres and cold chain all come back at once, and the set has to hold them.

  • Silent canopy for siting near wards and residential blocks
  • Automatic transfer under ten seconds, with the sequence tested and logged
  • Fuel polishing and day tanks where the set may sit idle for months

200 kW to 1200 kW, silent and containerised

Construction & EPC generator set application

Construction & EPC

The set moves every few weeks, gets run by whoever is on site, and has to survive being loaded on and off a truck.

  • Trailer-mounted and road-legal, single or double axle
  • Lockable panels and single-key service access for site conditions
  • Reinforced base frame and lifting points rated for the fully fuelled weight

60 kW to 500 kW, mobile and trailer mounted

Agriculture & Farming generator set application

Agriculture & Farming

Long, seasonal running hours at low load, in dust, with maintenance done by the farm rather than a contractor.

  • Controls kept simple enough for on-site operation
  • Sized above the pump starting surge rather than at the running load
  • Cold-weather package where the set sits idle through winter

30 kW to 350 kW, open or silent

Rental Fleets generator set application

Rental Fleets

A rental set is judged on how fast it goes out, how rarely it comes back, and whether any operator can run it.

  • Standardised fleet specification across all units
  • Lockable panels with single-key access and tamper-resistant metering
  • Documented service intervals with parts swap designed to be quick

60 kW to 800 kW, mobile and silent

Telecom & Towers generator set application

Telecom & Towers

A tower site is unattended by definition: the set runs for years without an operator present, and every site visit costs a day of driving.

  • Long fuel autonomy with a base tank sized for the real refuelling route
  • Remote monitoring of run hours, alarms and fuel level over GSM or IP
  • Hybrid-ready configuration for solar and battery integration

10 kW to 200 kW, silent, hybrid-ready

Oil & Gas generator set application

Oil & Gas

Remote wellheads, camps and pipeline stations run 24/7 far from the grid, in terrain where a breakdown means a convoy, not a service call.

  • Continuous-duty specification sized for non-stop camp and process load
  • Containerised or skid builds rated for overland transport to remote sites
  • Oversized cooling and two-stage filtration for dust and high ambient

200 kW to 2000+ kW, containerised and paralleled

Site conditions we have not listed.

Quarries above 3,000 m, coastal sites with salt air, hospitals with lifts on the standby bus, cold stores that cannot lose temperature, camps where the set is the only source of power. Send the altitude, the ambient temperature, the duty and the load list, and we will size to your site rather than to a reference condition.

Send four numbers and we can size it

  • Site altitude above sea level
  • Design ambient temperature in the hot season
  • Duty: standby, prime or continuous
  • The load list, including the largest motor to be started
Send the load list