KINBOOST

KB Series 800-1200 kW Generator Sets

Diesel and gas sets from 800-1200 kW with 31 engine configurations across 7 brands: open, silent, mobile and containerised builds, 50/60 Hz.

800-1200 kW generator sets
Power band800-1200 kWEngine options31BrandsCummins, Pangu, Shangchai, Mercedes-Benz MTU, Weichai, Yuchai, PerkinsFrequency50 / 60 HzCustomization
Open (weatherproof)SilentMobile / TrailerContainerizedATSAlternatorColor optionsOEM / ODM
Applications
Prime powerStandby backupRental fleetsIndustrial plantsConstructionMining
See how these sites are powered →
Request a quote for this modelFull datasheet, load-bank test report and O&M manual ship with the unit. See the document pack

What's included

  • Engine, alternator and controller coupled and tested as one set
  • Base frame with anti-vibration mounts; day tank or external tank per build
  • Silent canopy / trailer / container per selected build type
  • Battery set, exhaust silencer and flexible bellows
  • Factory load-bank test report (0 / 50 / 75 / 100% load)
  • Packing for sea freight; destination certificates per market
Open Type generator set built in this power band
Open Type
Silent Type generator set built in this power band
Silent Type
Mobile / Trailer Type generator set built in this power band
Mobile / Trailer Type
Containerized Type generator set built in this power band
Containerized Type

Engine variants & specifications

Indicative data based on engine OEM matching sheets. Fuel consumption calculated at 75% of prime rating.

ModelPrime powerEngine brandEngine modelCylindersDisplacementLube oilFuel @75%DimensionsWeight
KB-850GF850 kWCumminsKTA38-G7E1238 L135 L155 L/h4600*1800*24508200 kg
KB-850GF850 kWCumminsKTA38-G7E1238 L135 L155 L/h4600*1800*24508200 kg
KB-900GF900 kWCumminsKTA38-G9E838 L135 L164.1 L/h4500*1750*24509200 kg
KB-900GF900 kWCumminsKTA38-G9E838 L135 L164.1 L/h4500*1750*24509200 kg
KB-900GF900 kWMercedes-Benz MTU18V2000G651835.82 L135 L160.1 L/h4500*1910*24307225 kg
KB-900GF900 kWPanguHTAA32EG716132 L145 L25.1 L/h5000*2000*22009600 kg
KB-900GF900 kWShangchai6WTAA35-G3101035.1 L55 L155.2 L/h5000*2000*22009600 kg
KB-900GF900 kWWeichai12M33D1108E200839.2 L113 L169.8 L/h5000*2000*21009600 kg
KB-900GF900 kWWeichai12M33D1108E3101039.2 L146 L157.6 L/h5000*2000*22009600 kg
KB-900GF900 kWYuchaiYC6C1520-D311245 L150 L161846.4 L/h5000*2000*22009600 kg
KB-1000GF1000 kWCumminsKTA50-G31050 L177 L182.3 L/h5000*2000*255010100 kg
KB-1000GF1000 kWCumminsQSK38-G51238 L177 L182.3 L/h4700*2500*275011050 kg
KB-1000GF1000 kWPanguHTAA40EG320132 L145 L35 L/h5300*2200*260010000 kg
KB-1000GF1000 kWPerkins4012-46TWG2A1245.8 L159 L143883.2 L/h4770*1780*25009000 kg
KB-1000GF1000 kWShangchai6WTAA35-G3111035.1 L75 L172.5 L/h5300*2200*260010000 kg
KB-1000GF1000 kWWeichai12M33D1108E3101239.2 L146 L175.1 L/h5000*2000*22009600 kg
KB-1000GF1000 kWWeichai12M33D1210E2001039.2 L146 L188.6 L/h5300*2200*260010000 kg
KB-1000GF1000 kWYuchaiYC12VTD1680-D301239.2 L150 L136688.6 L/h5300*2200*260010000 kg
KB-1100GF1100 kWCumminsKTA50-G7E1250 L204 L200.6 L/h5300*2100*255010000 kg
KB-1100GF1100 kWCumminsKTA50-G81050 L204 L200.6 L/h5100*2200*265012000 kg
KB-1100GF1100 kWMercedes-Benz MTU12V4000G23R1257.2 L173 L195.6 L/h4150*1670*23809820 kg
KB-1100GF1100 kWPanguSTAA40EG316180 L195 L39.5 L/h5100*2080*25009900 kg
KB-1100GF1100 kWWeichai12M33D1320E2001039.2 L146 L207.5 L/h5400*2000*250013000 kg
KB-1100GF1100 kWWeichai12M33D1320E3101239.2 L146 L192.7 L/h5100*1980*28009900 kg
KB-1100GF1100 kWYuchaiYC12VTD1830-D301279.2 L150 L150357.5 L/h5100*2000*25009900 kg
KB-1200GF1200 kWCumminsKTA50-G8E1650 L204 L218.8 L/h5700*2200*255010500 kg
KB-1200GF1200 kWCumminsKTA50-G8E1650 L204 L218.8 L/h5700*2300*250010500 kg
KB-1200GF1200 kWPerkins4012-46TAG2A1245.8 L159 L172659.9 L/h5000*2120*251010000 kg
KB-1200GF1200 kWWeichai12M33D1320E2001239.2 L146 L226.3 L/h5500*2100*260014000 kg
KB-1200GF1200 kWWeichai12M33D1500E3101252.3 L180 L210.2 L/h5400*2200*260011000 kg
KB-1200GF1200 kWYuchaiYC12VTD2000-D301239.2 L340 L215795.2 L/h5400*2500*260011000 kg

Features

OEM engine matching

Nine engine series matched to the same alternator and controller platform, so a brand swap never changes the rest of the set.

100% load-bank tested

Every set runs 0 / 50 / 75 / 100% before dispatch. Report and video ship with the machine.

Built for the grid you have

50 Hz and 60 Hz windings, any standard voltage, DER1/DER2 or DSE controllers to match your site.

Destination-ready

SONCAP, SASO, GOST/EAC and COC/PVoC documentation prepared before the container is sealed.

What your site takes away from the nameplate.

Hot, thin air carries less oxygen, so a set makes less power than the catalogue figure. This table is a planning guide for sizing, not a substitute for the derate curve in the formal datasheet.

Sea level to 500 m1.00
1,000 m0.965
1,500 m0.948
2,000 m0.93
3,000 m0.895

Worked example

  • A set rated 500 kW prime at reference conditions.
  • Site at 1,500 m altitude and 45 °C ambient.
  • Altitude factor 0.948, ambient factor 0.99.
  • Usable output is about 500 x 0.948 x 0.99, or 469 kW.

469 kW usable, against a 500 kW nameplate.

Full derating tables and site sizing

Prime, standby or continuous. The label changes the price.

The same machine carries three different numbers depending on which rating you buy. Sizing to the wrong one is the most expensive mistake in a generator project, so here is the definition we quote against.

ESPStandby power

Rated output available for the duration of a mains outage, with a limited annual running hour allowance. No overload capability. The cheapest rating, and the right one for backup only.

PRPPrime power

Rated output available continuously under varying load, with a 10% overload permitted for one hour in twelve. This is the rating most industrial and mining sites should buy.

COPContinuous power

Rated output available for unlimited hours at a constant load. No overload capability. Required where the set is the only source of power rather than a backup.

ISO 8528-1 defines the three ratings above. Reference conditions are 25 °C ambient, 100 m altitude and 30% relative humidity. Every value we publish is stated at those conditions unless the row says otherwise.

What arrives in the container besides the set.

Every unit ships with the documents below, prepared against its own serial number, plus whichever destination certificate your market requires.

Export-crated generator sets prepared for dispatch at the KINBOOST plant
  1. 01Commercial invoice and packing list
  2. 02Bill of lading or airway bill
  3. 03Certificate of origin (Form E / FTA as applicable)
  4. 04Signed load-bank test report with unit serial number
  5. 05Operation and maintenance manual
  6. 06Electrical schematic and control wiring diagram
  7. 07Spare parts list keyed to the unit serial number
  8. 08Warranty certificate

Request a quote for this model